Technical reference
Generator and converter
The generator converts the rotor’s mechanical power into electricity; the converter matches it to the frequency and voltage of the grid. The arrangement used — DFIG, full-power converter or gearless direct drive — decides what to look at in the field.
General reference. Values, limits, intervals and torques vary by turbine type; the OEM documentation always governs.
Main parts
- DFIG: stator connected to the grid, rotor through a converter that carries only part of the power (often around a third)
- Full-power converter: all power passes through the converter
- Gearless direct drive: a large multi-pole ring generator turned directly by the rotor; all power through the converter
- Winding temperature sensors (usually PT100), bearings, cooling, slip rings and brushes (DFIG), encoder
Common faults and where to look first
- Winding temperature alarm: compare channels, verify the measuring chain, then cooling
- Brush wear, marks on the slip ring: brush length and pressure, ring surface, dust
- Converter overcurrent: match events to conditions, cooling, connections, grid events
Safety
The converter stores energy in its DC link and carries an arc-flash risk. Cabinets are never opened under load; apply LOTO, wait for the discharge time and verify zero voltage. Authorised personnel only.
Full version