Model guide
Enercon E-92
2.35 MW rated power, 92 m rotor. A larger rotor but a lower rating than the E-82 — that choice explains the whole E-92: it was designed to stay in production for more of the year on low- and medium-wind sites.
Why a larger rotor and a smaller rating?
Rated power is the turbine’s ceiling, reached only in strong enough wind. On a weak-wind site the turbine spends most of its time below it. What counts there is not a high ceiling but useful power in light wind.
A larger rotor collects more energy from the same weak wind; a lower rating keeps the generator and power electronics at a point they reach early. The result is an earlier start and a high capacity factor. On a strong-wind site the same choice wastes potential.
Key technical data
| Parameter | Value |
|---|---|
| Rated power | 2.35 MW |
| Rotor diameter | 92 m |
| Hub height | 78–138 m |
| Rotor speed | up to 16 rpm |
| Cut-in | 2 m/s |
| Rated wind speed | 13 m/s |
| Drivetrain | Gearless, direct drive |
| Generator | Synchronous, wound |
| Nacelle mass | 64 t |
| Rotor + hub mass | 41 t |
| Wind class | IEC IIA |
Drivetrain and systems
Low speed, high torque
- For the same power, lower speed means higher torque; the annular generator and rotor connections carry that load.
Annular generator and heat
- A turbine that stays in production for long hours in light wind keeps its generator cooling working constantly; clean air paths are a first-order concern.
Yaw
- A larger rotor means a higher moment on the yaw system; lubrication of the adjustment gears and the damping are followed.
E-82 and E-92 (Enercon)
| Item | E-82 E2 | E-92 |
|---|---|---|
| Rated power | 2.0 / 2.3 MW | 2.35 MW |
| Rotor diameter | 82 m | 92 m |
| Rotor speed | 6–19.5 rpm | up to 16 rpm |
Maintenance topics that matter in the field
- Generator cooling air paths and filters.
- Pitch emergency supply and connections.
- Yaw adjustment gears and lubrication.
- Blade surface and root connections: periodic visual checks on a long blade.
Sources
Warning: Every job in the nacelle, hub and tower follows lockout–tagout (LOTO), rotor lock and the manufacturer’s safety instructions. This page is field experience and published data; it does not replace the service documentation.